BMS

Seplos SP-HV-36S 36S High Voltage BMS

High Voltage Battery Management System for Energy Storage

An integrated high voltage BMS combining BCU, BMU and intelligent fan control for real-time battery monitoring, protection, balancing and CAN/RS485 communication in energy storage systems.
Model
SP-HV-36S
Chemistry
LiFePO4 / Lithium Chemistries
Up to 1500V

System Voltage

19–36S per BMU

Cell Configuration

LiFePO4 / Lithium Chemistries

Battery Chemistry

CAN / RS485

Communication

PRODUCT OVERVIEW

High-Voltage Protection, Monitoring & Battery Control

The SP-HV-36S integrates battery control, cell monitoring, communication and thermal management to support reliable operation of high-voltage lithium battery energy storage systems.

Built for Scalable High-Voltage Energy Storage Systems

The Seplos SP-HV-36S integrates a Battery Control Unit (BCU), Battery Monitoring Unit (BMU) and intelligent fan control into a coordinated high-voltage battery management solution. The BCU provides protection against overcharge, over-discharge, overcurrent, high temperature and low temperature, together with a multi-level alarm mechanism.

The BMU performs real-time voltage and temperature monitoring at cell level and supports 19–36 cell nodes. Isolated CAN and RS485 communication, passive balancing, fan control and fault detection help support flexible integration into high-voltage energy storage systems.

Designed for High-Voltage System Integration
Supports high-voltage energy storage architectures up to 1500V with CAN/RS485 communication, automatic coding, cell monitoring and coordinated BCU/BMU management.
CORE FEATURES

Battery Protection

Multi-level protection against overcharge, over-discharge, overcurrent and abnormal battery temperatures.

Precision Cell Monitoring

Real-time cell voltage and temperature sampling helps track battery status and detect abnormal conditions.

CAN & RS485 Communication

Isolated CAN and RS485 interfaces support real-time communication between BMU, BCU and compatible system controls.

Balancing & Thermal Control

Up to 200mA passive balancing with temperature-based fan control and PWM speed regulation.

TECHNICAL SPECIFICATIONS

Technical Data for BMS Evaluation

Review the key electrical, environmental and communication parameters before confirming battery configuration and system compatibility.

SP-HV-36S

Core BMS Parameters

Use these values for preliminary battery pack, inverter and current matching before final technical confirmation.

LiFePO4 / Lithium Chemistries
Battery Chemistry
Up to 1500V System
Nominal Voltage
19–36S per BMU
Battery Configuration
Rated Current
BCU / BMU Real-Time Monitoring
Monitoring
Parameter Specification
Supported System Voltage < 1500V
BMU Supply Voltage 12V / 24V (12–30V)
Rated Power Consumption < 3W
Static Power Consumption < 100μA
Cell Voltage Sampling Range 0–5V
Voltage Sampling Accuracy < 15mV (-40°C to 125°C)
Cell Nodes 19–36
Temperature Sampling Range -40°C to 125°C
Temperature Accuracy ±2°C
Sampling Period 200ms
Temperature Channels 16 Cell + 2 Terminal
CAN Communication 125–1000kbps; default 250kbps
RS485 Communication 9600–115200bps; default 9600bps
Fan Supply 12V / 24V
Fan Drive ≤10W
Fan ON Cell 40°C / Terminal 85°C
Fan OFF Cell 35°C / Terminal 75°C
Balancing Passive Balancing / 200mA
Automatic Coding Supported
Working Temperature -40°C to 85°C
Working Humidity 5–90%
COMPATIBILITY & APPLICATION

Confirm Battery and System Compatibility Before Ordering

Check battery chemistry, series configuration, current requirements and communication compatibility before confirming your BMS selection.

Designed for Flexible Battery System Integration

Use the core product data below as a quick matching reference. Final compatibility should be confirmed against your battery pack and inverter requirements.

BATTERY CHEMISTRY

LiFePO4 / Lithium Chemistries

COMMUNICATION

CAN / RS485

MONITORING

BCU / BMU Real-Time Monitoring

System Voltage

Up to 1500V

High Voltage Battery Systems
Solar Energy Storage
Commercial Energy Storage
Battery System Integration
BEFORE ORDERING

Prepare These System Details

Need Help Selecting the Right BMS?

Share your battery chemistry, series configuration, nominal voltage, maximum current and inverter model. Our technical team can help confirm BMS compatibility before ordering.

Your project information will only be used to evaluate your inquiry and provide relevant product or technical support.