BMS

Seplos SP-HV-18S 18S High Voltage BMS

High Voltage Battery Monitoring Unit for Energy Storage

The Seplos SP-HV-18S high voltage BMS integrates BCU, BMU and intelligent fan control for real-time cell monitoring, battery protection, passive balancing and CAN/RS485 communication in high-voltage energy storage systems.
Model
SP-HV-18S
Chemistry
LiFePO4 / Lithium Chemistries
Up to 1500V

System Voltage

4–18S per BMU

Cell Configuration

LiFePO4 / Lithium Chemistries

Battery Chemistry

CAN / RS485

Communication

PRODUCT OVERVIEW

High-Voltage Cell Monitoring, Protection & Control

Designed for high-voltage lithium battery systems, the SP-HV-18S combines accurate cell monitoring, system communication, passive balancing and thermal management for reliable energy storage operation.

Built for Flexible High-Voltage Battery Systems

The Seplos SP-HV-18S is a high-voltage battery management solution integrating a Battery Control Unit (BCU), Battery Monitoring Unit (BMU) and intelligent cooling fan control. The BCU can support high-voltage battery systems while providing protection against overcharge, over-discharge, overcurrent, high temperature and low temperature conditions.

The BMU performs precise real-time sampling of individual cell voltage and temperature and supports 4–18 cell nodes. CAN and RS485 communication allow battery data to be transmitted to the BCU, while passive balancing, fan control and fault detection help improve battery consistency, thermal management and system reliability.

Designed for High-Voltage System Integration
Supports high-voltage battery architectures up to 1500V with isolated CAN/RS485 communication, automatic coding, passive balancing and coordinated BCU/BMU management.
CORE FEATURES

Battery Protection

Multi-level protection helps protect the battery system from overcharge, over-discharge, overcurrent and abnormal temperature conditions.

Precision Cell Monitoring

Real-time cell voltage and temperature sampling supports accurate battery status monitoring and fault detection.

CAN & RS485 Communication

Isolated CAN and RS485 interfaces enable reliable real-time communication between the BMU, BCU and compatible system controls.

Balancing & Thermal Control

Up to 200mA passive balancing combines with intelligent fan control and PWM speed regulation for improved cell consistency and thermal management.

TECHNICAL SPECIFICATIONS

Technical Data for BMS Evaluation

Review the key electrical, environmental and communication parameters before confirming battery configuration and system compatibility.

SP-HV-18S

Core BMS Parameters

Use these values for preliminary battery pack, inverter and current matching before final technical confirmation.

LiFePO4 / Lithium Chemistries
Battery Chemistry
Up to 1500V System
Nominal Voltage
4–18S per BMU
Battery Configuration
Rated Current
BCU / BMU Real-Time Monitoring
Monitoring
ParameterSpecification
Supported System Voltage< 1500V
BMU Supply Voltage12V / 24V (12–30V)
Rated Power Consumption< 3W
Static Power Consumption< 100μA
Cell Voltage Sampling Range0–5V
Voltage Sampling Accuracy< 15mV (-40°C to 125°C)
Cell Nodes4–18
Temperature Sampling Range-40°C to 125°C
Temperature Accuracy±2°C
Sampling Period200ms
Temperature Channels9
CAN Communication125–1000kbps; Default 250kbps
RS485 Communication9600–115200bps; Default 9600bps
Fan Supply Voltage12V / 24V
Fan Drive Power≤10W
Fan ON TemperatureCell 40°C / Terminal 85°C
Fan OFF TemperatureCell 35°C / Terminal 75°C
BalancingPassive Balancing / 200mA
Automatic CodingSupported / With Coding Wire
Working Temperature-40°C to 85°C
Working Humidity5–90%
COMPATIBILITY & APPLICATION

Confirm Battery and System Compatibility Before Ordering

Check battery chemistry, series configuration, current requirements and communication compatibility before confirming your BMS selection.

Designed for Flexible Battery System Integration

Use the core product data below as a quick matching reference. Final compatibility should be confirmed against your battery pack and inverter requirements.

BATTERY CHEMISTRY

LiFePO4 / Lithium Chemistries

COMMUNICATION

CAN / RS485

MONITORING

BCU / BMU Real-Time Monitoring

System Voltage

Up to 1500V

High Voltage Battery Systems
Solar Energy Storage
Commercial Energy Storage
Battery System Integration
BEFORE ORDERING

Prepare These System Details

Need Help Selecting the Right BMS?

Share your battery chemistry, series configuration, nominal voltage, maximum current and inverter model. Our technical team can help confirm BMS compatibility before ordering.

Your project information will only be used to evaluate your inquiry and provide relevant product or technical support.