HYBRID INVERTER
SEPLOS HYBRID INVERTER

Seplos 3–30kW Three Phase Hybrid Inverter

High-voltage three-phase hybrid inverter for residential and commercial energy storage, with 3–30kW power options, intelligent energy management and backup power support.

MODEL
AF3K-TH – AF30K-TH
MINIMUM ORDER
1 Unit
LEAD TIME
15 Days
PRODUCT TYPE
Hybrid Inverter
APPLICATION
Residential / Commercial ESS
AVAILABILITY
● Made to Order

Need help matching the inverter with your battery voltage, PV system or grid configuration? Our engineering team can help.

3–30kW Three Phase
Core configuration at a glance
RATED POWER
3–30kW
PHASE TYPE
Three Phase
BATTERY VOLTAGE
150–800V
MAX EFFICIENCY
98.5%
HYBRID INVERTER PLATFORM

Product Overview & Core Features

Designed for solar energy storage systems requiring efficient power conversion, flexible battery integration and reliable grid or backup operation.

SEPLOS HYBRID INVERTER

Scalable Three-Phase Power for Residential & Commercial Energy Storage

The Seplos 3–30kW Three Phase Hybrid Inverter is designed for high-voltage residential and commercial energy storage systems, combining solar PV conversion, battery management, grid interaction and backup power within one flexible platform.

With a wide 3–30kW power range and support for 150–800V high-voltage batteries, the series can be configured for different system sizes while supporting intelligent energy management, reliable backup operation and flexible three-phase load requirements.

TYPICAL APPLICATIONS
Residential ESS
Commercial ESS
Solar + Battery Storage
ENGINEERING HIGHLIGHTS
4 CORE FEATURES

01

Flexible Energy Management

Time-of-use optimization and built-in anti-feed-in control help manage solar, battery and grid energy more efficiently.

02

Reliable Backup Power

UPS switching in less than 10 ms and up to 150% peak output in backup mode help maintain power for critical loads.

03

100% Unbalanced Output

Supports 100% unbalanced three-phase output for more flexible load distribution across residential and commercial power systems.

04

Integrated Safety Protection

Optional AFCI protection and rapid-shutdown readiness provide additional safety support for solar and energy storage installations.

Engineered for Flexible Solar & Energy Storage Integration

Battery, PV, grid and application compatibility are detailed in the system integration section below.

APPLICATION CLASS
Residential / Commercial ESS
BATTERY PLATFORM
High Voltage ESS
HYBRID ENERGY SYSTEM

System Architecture & Energy Flow

See how the Seplos hybrid inverter connects solar PV, battery storage,the utility grid and electrical loads within one integrated energy system.

INTEGRATED ENERGY ARCHITECTURE
● BIDIRECTIONAL ENERGY FLOW
ENERGY SOURCE
Solar PV

Solar Power Input

ENERGY STORAGE
Battery Storage

Charge & Discharge

Rear connection view of Seplos 3–30kW three phase hybrid inverter showing cooling structure and power connection interfaces
SEPLOS HYBRID INVERTER
GRID CONNECTION
Utility Grid

Grid Interaction

POWER OUTPUT
Electrical Loads

Home & Commercial Loads

01
PV INPUT

Solar Generation

Converts DC solar energy for load supply, battery charging and grid interaction.

02
BATTERY

Energy Storage

Coordinates battery charging and discharging according to system demand and operating strategy.

03
GRID

Grid Interaction

Supports controlled energy exchange with the utility grid according to system configuration.

04
LOAD OUTPUT

Power Supply

Delivers AC power to residential or commercial loads with backup capability where supported.

ENGINEERING DATA

Technical Specifications

Detailed electrical, PV, battery, AC output and system specifications for this hybrid inverter.

HYBRID INVERTER PLATFORM

Key Electrical Data at a Glance

Review the key inverter configuration before confirming PV input, battery compatibility, grid connection and system integration requirements.

RATED POWER
3–30kW
MAX PV INPUT
6–51kW
BATTERY VOLTAGE
150–800V
PHASE TYPE
Three Phase
Need System Compatibility Confirmation?

Battery voltage, PV input, grid type and communication requirements should be confirmed before final system integration.

Product Technical Data

PV, battery, AC output, efficiency, protection and communication specifications.

PRODUCT DATA
ModelAF3K-THAF4K-THAF5K-THAF6K-THAF8K-THAF10K-TH
PV InputMax.DC Input Power (kW)567.591215
Max.PV Voltage (V)1000
Rated DC Input Voltage (V)620
DC Input Voltage Range (V)150-1000
MPPT Voltage Range (V)150-850
Full MPPT Range(V)200-850200-850200-850250-850300-850500-850
Start-up Voltage (V)160
Max.DC Input Current(A)20×2
Max. Short Current(A)30×2
No.of MPPT Tracker/Strings2/2
Battery PortBattery Nominal Voltage (V)200200200250300400
BatteryVoltage Range (V)150-800
Max. Charge/Discharge Current (A)30
Max. Charge/Discharge Power (kW)3456810
Charging Curve3 Stages
Compatible Battery TypeLi-ion/Lead-acid / Sodium metal chloride battery
AC GridNominal AC Output Power (kW)3456810
Max.AC Input/Output Power (kVA)4.5/3.36/4.47.5/5.59/6.612/8.815/11
Max.AC Output Current (A)5.378.510.513.517
Nominal AC Voltage (V)230/400
Nominal AC Frequency (Hz)50/60
Power Factor1(-0.8-0.8) adjustable
Current THD (%)<3%
AC Load Output (Back-up)Nominal Output Power (VA)3000400050006000800010000
Nominal Output Voltage (V)230/400
Nominal Output Frequency (Hz)50/60
Nominal Output Current (A)4.45.87.38.711.614.5
Peak Output Power3300VA, 60s4400VA, 60s5500VA, 60s6600VA, 60s8800VA, 60s11000VA, 60s
THDV (with linear load)<3%
Switching Time (ms)<10
EfficiencyEurope Efficiency97.50%
Max. Efficiency98.00%98.20%98.20%
Battery Charge/Discharge Efficiency98.00%
ProtectionReverse Polarity ProtectionYes
Over Current / Voltage ProtectionYes
Anti-islanding ProtectionYes
AC Short-circuit ProtectionYes
Leakage Current DetectionYes
Ground Fault MonitoringYes
Grid MonitoringYes
Enclosure Protect LevelIP65
AC/DC surge protectionType II
General DataDimensions (WxHx D,mm)558x535x260
Weight (kg)29
TopologyTransformerless
Cooling ConceptNatural Convection
Relative Humidity0-100%
Operating Temperature Range(℃)-25 to 60℃
Operating Altitude (m)<4000
Standby Consumption (W)<5
Display & Communication InterfacesLCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G
ModelAF12K-THAF15K-THAF17K-THAF20K-THAF25K-THAF30K-TH
PV InputMax.DC Input Power (kW)1822.525.53037.545
Max.PV Voltage (V)1000
Rated DC Input Voltage (V)620
DC Input Voltage Range (V)150-1000
MPPT Voltage Range (V)150-850
Full MPPT Range(V)500-850
Start-up Voltage (V)160
Max.DC Input Current(A)20×220+3232×232×240×240×2
Max. Short Current(A)30×230+4848×248×260×260×2
No.of MPPT Tracker/Strings2/22/32/42/42/42/4
Battery PortBattery Nominal Voltage (V)450500400500500550
BatteryVoltage Range (V)150-800
Max. Charge/Discharge Current (A)305050506060
Max. Charge/Discharge Power (kW)121517202530
Charging Curve3 Stages
Compatible Battery TypeLi-ion/Lead-acid / Sodium metal chloride battery
AC GridNominal AC Output Power (kW)121517202530
Max.AC Input/Output Power (kVA)18/13.222.5/16.525.5/18.730/2237.5/27.545/33
Max.AC Output Current (A)21.52730324048
Nominal AC Voltage (V)230/400
Nominal AC Frequency (Hz)50/60
Power Factor1(-0.8-0.8) adjustable
Current THD (%)<3%
AC Load Output (Back-up)Nominal Output Power (VA)120001500017000200002500030000
Nominal Output Voltage (V)230/400
Nominal Output Frequency (Hz)50/60
Nominal Output Current (A)17.421.824.72936.343.5
Peak Output Power13200VA,60s16500VA,60s18700VA,60s22000VA,60s27500VA,60s33000VA,60s
THDV (with linear load)<3%
Switching Time (ms)<10
EfficiencyEurope Efficiency97.50%97.50%97.80%97.80%98.00%98.10%
Max. Efficiency98.30%98.50%98.50%
Battery Charge/Discharge Efficiency98.00%
ProtectionReverse Polarity ProtectionYes
Over Current / Voltage ProtectionYes
Anti-islanding ProtectionYes
AC Short-circuit ProtectionYes
Leakage Current DetectionYes
Ground Fault MonitoringYes
Grid MonitoringYes
Enclosure Protect LevelIP65
AC/DC surge protectionType II
General DataDimensions (WxHx D,mm)558x535x260
Weight (kg)293636
TopologyTransformerless
Cooling ConceptIntelligent Fan
Relative Humidity0-100%
Operating Temperature Range(℃)-25 to 60℃
Operating Altitude (m)<4000
Standby Consumption (W)<5
Display & Communication InterfacesLCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G
ENERGY MANAGEMENT

Operating Modes & Energy Management

The Seplos hybrid inverter coordinates solar generation, battery storage, grid power and connected loads to support flexible energy use across different operating conditions.

SYSTEM OBJECTIVE

Maximize solar utilization, manage stored energy and maintain reliable power delivery.

01
PV → Loads → Battery
SELF-CONSUMPTION

Solar Self-Consumption

Solar power is prioritized for connected loads, with surplus energy available for battery charging or other configured system uses.

02
PV / Grid ↔ Battery
BATTERY MANAGEMENT

Battery Charge & Discharge

The inverter coordinates battery charging and discharging according to available solar power, load demand and system settings.

03
Inverter ↔ Utility Grid
GRID INTERACTION

Grid Energy Management

Grid import and export are managed according to system configuration, energy demand and applicable operating settings.

04
Battery → Inverter → Backup Loads
BACKUP OPERATION

Backup Power Support

When configured for backup operation, stored battery energy can support designated loads during grid interruptions.

SYSTEM COMPATIBILITY

Compatibility & Applications

Review key battery, grid and communication requirements before integrating the inverter into your energy storage system.

SYSTEM COMPATIBILITY

Key System Requirements

Confirm core electrical and communication requirements before final inverter integration.

01
BATTERY VOLTAGE
150–800V
02
BATTERY TYPE
Li-ion / Lead-acid / Sodium Metal Chloride
03
GRID TYPE
Three Phase
04
COMMUNICATION
RS485 / CAN / Wi-Fi / GPRS / 4G
TYPICAL APPLICATIONS

Designed for Flexible Energy Systems

Typical application scenarios vary by inverter model, power rating and system configuration.

01
Residential Energy Storage

Home solar and battery energy storage applications.

02
Solar + Battery Storage

Integrated solar generation and battery storage applications.

03
Backup Power

Flexible backup and energy management applications.

Confirm before installation: battery voltage. grid configuration and communication requirements should match the selected inverter model.

BUILD WITH CONFIDENCE

Ready to Build Your Mason Battery System?

Tell us your cell model, inverter brand and project requirements. Our team can help confirm compatibility, configuration and the right Mason DIY solution before you order.

Your project information will only be used to evaluate your inquiry and provide relevant product or technical support.